Storage Management Message Reference 53
2095 SCSI sense data. If 
this disk is part of a 
redundant virtual 
disk, select the 
"Offline" option and 
then replace the disk. 
Then configure a hot 
spare and it will start 
the rebuild 
automatically. If this 
disk is a hot spare, 
select the "Prepare to 
Remove" option and 
then replace the disk. 
If this disk is part of a 
non-redundant disk, 
you should back up 
your data 
immediately. If the 
disk fails, you will not 
be able to recover the 
data. 
Warning / 
Non-critical
Cause: An array disk has failed, is corrupt, or 
is otherwise experiencing a problem.
Action: Replace the array disk. Even though 
the disk may not have failed yet, it is strongly 
recommended that you replace the disk. 
Review the message text for 
additional information.
903 571
2098 Global hot spare 
assigned
Ok / 
Normal
Cause: A user has assigned an array disk as a 
global hot spare. This alert is provided for 
informational purposes.
Action: None
901 574
2099 Global hot spare 
unassigned
Ok / 
Normal
Cause: A user has unassigned an array disk as 
a global hot spare. This alert is provided for 
informational purposes.
Action: None
901 575
Table 4-1.  Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap 
Numbers
Array 
Manager 
Event 
Number