54 Storage Management Message Reference
2100 Temperature 
exceeded the 
maximum warning 
threshold
Warning / 
Non-critical
Cause: The array disk enclosure is too hot. 
A variety of factors can cause the excessive 
temperature. For example, a fan may have 
failed, the thermostat may be set too high, or 
the room temperature may be too hot.
Action: Check for factors that may cause 
overheating. For example, verify that the 
enclosure fan is working. You should also 
check the thermostat settings and examine 
whether the enclosure is located near a heat 
source. Make sure the enclosure has enough 
ventilation and that the room temperature is 
not too hot. See the enclosure 
documentation for more 
diagnostic information.
1053 591
2101 Temperature dropped 
below the minimum 
warning threshold
Warning / 
Non-critical
Cause: The array disk enclosure is too cool.
Action: Check whether the thermostat 
setting is too low and whether the room 
temperature is too cool.
1053 592
2102 Temperature 
exceeded the 
maximum failure 
threshold
Critical / 
Failure / 
Error
Cause: The array disk enclosure is too hot. 
A variety of factors can cause the excessive 
temperature. For example, a fan may have 
failed, the thermostat may be set too high, or 
the room temperature may be too hot.
Action: Check for factors that may cause 
overheating. For example, verify that the 
enclosure fan is working. You should also 
check the thermostat settings and examine 
whether the enclosure is located near a heat 
source. Make sure the enclosure has enough 
ventilation and that the room temperature is 
not too hot. See the enclosure documentation 
for more diagnostic information.
1054 593
2103 Temperature dropped 
below the minimum 
failure threshold 
Critical / 
Failure / 
Error
Cause: The array disk enclosure is too cool.
Action: Check whether the thermostat 
setting is too low and whether the room 
temperature is too cool.