Messages Reference Guide
Table Of Contents
- Dell OpenManage™ Server Administrator
- Messages Reference Guide
- Introduction
 - Event Message Reference
- Miscellaneous Messages
 - Temperature Sensor Messages
 - Cooling Device Messages
 - Voltage Sensor Messages
 - Current Sensor Messages
 - Chassis Intrusion Messages
 - Redundancy Unit Messages
 - Power Supply Messages
 - Memory Device Messages
 - Fan Enclosure Messages
 - AC Power Cord Messages
 - Hardware Log Sensor Messages
 - Processor Sensor Messages
 - Pluggable Device Messages
 
 - System Event Log Messages for IPMI Systems
 - Storage Management Message Reference
 - Index
 
 
 - Messages Reference Guide
 

Storage Management Message Reference 55
2104 Controller battery is 
reconditioning 
Ok / 
Normal
Cause: This alert is provided for 
informational purposes.
Action: None
1151 581
2105 Controller battery 
recondition is 
completed
Ok / 
Normal
Cause: This alert is provided for 
informational purposes.
Action: None
1151 582
2106 Smart FPT exceeded Warning / 
Non-critical
Cause: A disk on the specified controller has 
received a SMART alert (predictive failure) 
indicating that the disk is likely to fail in the 
near future.
Action: Replace the disk that has received the 
SMART alert. If the array disk is a member of 
a non-redundant virtual disk, then back up the 
data before replacing the disk. Removing an 
array disk that is included in a non-redundant 
virtual disk will cause the virtual disk to fail 
and may cause data loss.
903 585
2107 Smart configuration 
change
Critical / 
Failure / 
Error
Cause: A disk has received a SMART alert 
(predictive failure) after a configuration change. 
The disk is likely to fail in the near future.
Action: Replace the disk that has received the 
SMART alert. If the array disk is a member of 
a non-redundant virtual disk, then back up 
the data before replacing the disk. Removing 
an array disk that is included in a non-
redundant virtual disk will cause the virtual 
disk to fail and may cause data loss.
904 586
2108 Smart warning Warning / 
Non-critical
Cause: A disk has received a SMART alert 
(predictive failure). The disk is likely to fail in 
the near future.
Action: Replace the disk that has received the 
SMART alert. If the array disk is a member of 
a non-redundant virtual disk, then back up 
the data before replacing the disk. Removing 
an array disk that is included in a non-
redundant virtual disk will cause the virtual 
disk to fail and may cause data loss.
903 587
Table 4-1.  Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap 
Numbers
Array 
Manager 
Event 
Number