60 Storage Management Message Reference
2123 Redundancy lost Warning / 
Non-critical
Cause: A virtual disk or an enclosure has lost 
data redundancy. In the case of a virtual disk, 
one or more array disks included in the virtual 
disk have failed. Due to the failed array disk 
or disks, the virtual disk is no longer 
maintaining redundant (mirrored or parity) 
data. The failure of an additional array disk 
will result in lost data. In the case of an 
enclosure, more than one enclosure 
component has failed. For example, the 
enclosure may have suffered the loss of all 
fans or all power supplies.
Action: Identify and replace the failed 
components. To identify the failed 
component, select the Storage object and 
click the Health subtab. The controller status 
displayed on the Health subtab indicates 
whether a controller has a failed or degraded 
component. Click the controller that displays 
a Warning or Failed status. This action 
displays the controller Health subtab which 
displays the status of the individual controller 
components. Continue clicking the 
components with a Warning or Health status 
until you identify the failed component. See 
the online help for more information. See the 
enclosure documentation for information on 
replacing enclosure components and for 
other diagnostic information.
1306 None
2124 Redundancy normal  Ok / 
Normal
Cause: Data redundancy has been restored to 
a virtual disk or an enclosure that previously 
suffered a loss of redundancy.
Action: This alert is provided for 
informational purposes.
1304 None
Table 4-1.  Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap 
Numbers
Array 
Manager 
Event 
Number