62 Storage Management Message Reference
2132 Driver version 
mismatch
Warning / 
Non-critical
Cause: The controller driver is not a 
supported version.
Action: Install a supported version of the 
driver. If you do not have a supported driver 
version available, it can be downloaded from 
the Dell support site at support.dell.com. 
If you do not have a supported version of the 
driver available, check with your support 
provider for information on how to obtain the 
most current driver.
753 None
2135 Array Manager is 
installed on the 
system
Warning / 
Non-critical
Cause: Storage Management has been 
installed on a system that has an Array 
Manager installation.
Action: Installing Storage Management and 
Array Manager on the same system is not a 
supported configuration. Uninstall either 
Storage Management or Array Manager.
103 None
2136 Virtual disk 
initialization
Ok / 
Normal
Cause: Virtual disk initialization is in 
progress. This alert is provided for 
informational purposes.
Action: None
1201 None
Table 4-1.  Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap 
Numbers
Array 
Manager 
Event 
Number