Messages Reference Guide
Table Of Contents
- Dell OpenManage™ Server Administrator
- Messages Reference Guide
- Introduction
 - Event Message Reference
- Miscellaneous Messages
 - Temperature Sensor Messages
 - Cooling Device Messages
 - Voltage Sensor Messages
 - Current Sensor Messages
 - Chassis Intrusion Messages
 - Redundancy Unit Messages
 - Power Supply Messages
 - Memory Device Messages
 - Fan Enclosure Messages
 - AC Power Cord Messages
 - Hardware Log Sensor Messages
 - Processor Sensor Messages
 - Pluggable Device Messages
 
 - System Event Log Messages for IPMI Systems
 - Storage Management Message Reference
 - Index
 
 
 - Messages Reference Guide
 

Storage Management Message Reference 67
2163 Rebuild completed 
with errors
Ok / 
Normal
See the online help for more information. 904 690
2164 See the Readme file 
for a list of validated 
controller driver 
versions
Ok / 
Normal
Cause: Storage Management is unable to 
determine whether the system has the 
minimum required versions of the RAID 
controller drivers.
Action: This alert is generated for 
informational purposes. See the Readme file 
for driver and firmware requirements. In 
particular, if Storage Management 
experiences performance problems, you 
should verify that you have the minimum 
supported versions of the drivers and 
firmware installed.
101 None
2165 The RAID controller 
firmware and driver 
validation was not 
performed. The 
configuration file 
cannot be opened.
Warning / 
Non-critical
Cause: Storage Management is unable to 
determine whether the system has the 
minimum required versions of the RAID 
controller firmware and drivers. This 
situation may occur for a variety of reasons. 
For example, the installation directory path 
to the configuration file may not be correct. 
The configuration file may also have been 
removed or renamed.
Action: Reinstall Storage Management
753 None
2166 The RAID controller 
firmware and driver 
validation was not 
performed. The 
configuration file is 
out of date or 
corrupted.
Warning / 
Non-critical
Cause: Storage Management is unable to 
determine whether the system has the 
minimum required versions of the RAID 
controller firmware and drivers. This 
situation has occurred because a 
configuration file is unreadable or missing 
data. The configuration file may be 
corrupted.
Action: Reinstall Storage Management.
753 None
Table 4-1.  Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap 
Numbers
Array 
Manager 
Event 
Number