68 Storage Management Message Reference
2167 The current kernel 
version and the non-
RAID SCSI driver 
version are older than 
the minimum 
required levels.
See the Readme file 
for a list of validated 
kernel and driver 
versions.
Warning / 
Non-critical
Cause: The version of the kernel and the 
driver do not meet the minimum 
requirements. Storage Management may not 
be able to display the storage or perform 
storage management functions until you have 
updated the system to meet the minimum 
requirements.
Action: See the Readme file for kernel and 
driver requirements. Update the system to 
meet the minimum requirements and then 
reinstall Storage Management.
103 None
2168 The non-RAID SCSI 
driver version is older 
than the minimum 
required level.
See the Readme file 
for the validated 
driver version.
Warning / 
Non-critical
Cause: The version of the driver does not 
meet the minimum requirements. Storage 
Management may not be able to display the 
storage or perform storage management 
functions until you have updated the system 
to meet the minimum requirements.
Action: See the Readme file for the driver 
requirements. Update the system to meet the 
minimum requirements and then reinstall 
Storage Management.
103 None
2169 The controller battery 
needs to be replaced.
Critical / 
Failure / 
Error
Cause: The controller battery cannot 
recharge. The battery may be old or it may 
have been already recharged the maximum 
number of times. In addition, the battery 
charger may not be working.
Action: Replace the battery pack.
1154 None
2170 The controller battery 
charge level is normal.
Ok / 
Normal
Cause: This alert is provided for 
informational purposes.
Action: None
1151 None
Table 4-1.  Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap 
Numbers
Array 
Manager 
Event 
Number