70 Storage Management Message Reference
2178 The controller battery 
Learn cycle has 
timed out.
Warning / 
Non-critical
Cause: The controller battery must be fully 
charged before the Learn cycle can begin. 
The battery may be unable to maintain a full 
charge causing the Learn cycle to timeout. 
Additionally, the battery must be able to 
maintain cached data for a specified period of 
time in the event of a power loss. For 
example, some batteries maintain cached 
data for 24 hours. If the battery is unable to 
maintain cached data for the required period 
of time, then the Learn cycle will timeout.
Action: Replace the battery pack as the 
battery is unable to maintain a full charge.
1153 None
2179 The controller battery 
Learn cycle has been 
postponed.
Ok / 
Normal
Cause: This alert is provided for 
informational purposes.
Action: None
1151 None
2180 The controller battery 
Learn cycle will start 
in %1 days.
NOTE: The %1 is a 
variable that will be 
filled in with the 
number of days before 
which the Learn cycle 
will start. You can set 
the duration to start 
the Learn cycle.
Ok / 
Normal
Cause: This alert is provided for 
informational purposes.
Action: None
1151 None
Table 4-1.  Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap 
Numbers
Array 
Manager 
Event 
Number