74 Storage Management Message Reference
2202 A global hot spare has 
been removed.
Warning / 
Non-critical
Cause: The controller is unable to 
communicate with a disk that is assigned as a 
global hot spare. The disk may have been 
removed. There may also be a bad or loose 
cable.
Action: Check if the disk is healthy and that 
it has not been removed. Check the cables. 
If necessary, replace the disk and reassign the 
hot spare.
903 None
2203 A dedicated hot spare 
failed.
Warning / 
Non-critical
Cause: The controller is unable to 
communicate with a disk that is assigned as a 
dedicated hot spare. The disk may have failed 
or been removed. There may also be a bad or 
loose cable.
Action: Check if the disk is healthy and that 
it has not been removed. Check the cables. 
If necessary, replace the disk and reassign the 
hot spare.
903 None
2204 A dedicated hot spare 
has been removed.
Warning / 
Non-critical
Cause: The controller is unable to 
communicate with a disk that is assigned as a 
dedicated hot spare. The disk may have been 
removed. There may also be a bad or 
loose cable.
Action: Check if the disk is healthy and that 
it has not been removed. Check the cables. 
If necessary, replace the disk and reassign the 
hot spare.
903 None
2205 A dedicated hot spare 
has been 
automatically 
unassigned.
Warning / 
Non-critical
Cause: The hot spare is no longer required 
because the virtual disk it was assigned to has 
been deleted.
Action: None.
903 None
Table 4-1.  Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap 
Numbers
Array 
Manager 
Event 
Number