Storage Management Message Reference 75
2206 The only hot spare 
available is a SATA 
disk. SATA disks 
cannot replace SAS 
disks.
Warning / 
Non-critical
Cause: The only array disk available to be 
assigned as a hot spare is using SATA 
technology. The array disks in the virtual disk 
are using SAS technology. Due to this 
difference in technology, the hot spare cannot 
rebuild data if one of the array disks in the 
virtual disk fails.
Action: Add a SAS disk that is large enough 
to be used as the hot spare and assign the new 
disk as a hot spare.
903 None
2207 The only hot spare 
available is a SAS 
disk. SAS disks 
cannot replace SATA 
disks.
Warning / 
Non-critical
Cause: The only array disk available to be 
assigned as a hot spare is using SAS 
technology. The array disks in the virtual disk 
are using SATA technology. Due to this 
difference in technology, the hot spare cannot 
rebuild data if one of the array disks in the 
virtual disk fails.
Action: Add a SATA disk that is large enough 
to be used as the hot spare and assign the new 
disk as a hot spare.
903 None
2211 The physical disk is 
not supported.
Warning / 
Non-critical
Cause: The physical disk may not have a 
supported version of the firmware or the disk 
may not be supported by Dell.
Action: If the disk is supported by Dell, 
update the firmware to a supported version. 
If the disk is not supported by Dell, replace 
the disk with one that is supported.
903 None
2232 The controller alarm 
is silenced.
Ok / 
Normal
Cause: This alert is provided for 
informational purposes.
Action: None
751 None
2233 The BGI rate has 
changed.
Ok / 
Normal
Cause: This alert is provided for 
informational purposes.
Action: None
751 None
2234 The "Patrol Read" rate 
has changed.
Ok / 
Normal
Cause: This alert is provided for 
informational purposes.
Action: None
751 None
Table 4-1.  Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap 
Numbers
Array 
Manager 
Event 
Number