2266 Controller log file 
entry: %1
%1 is a substitution 
variable that will 
appear in the alert 
description for 
specific details about 
the alert.
Ok / 
Normal
Cause: This alert is provided for 
informational purposes.
Action: None
751 None
2267 The controller 
reconstruct rate has 
changed.
Ok / 
Normal
Cause: This alert is provided for 
informational purposes.
Action: None
751 None
2268 %1, Storage 
Management has lost 
communication with 
this RAID controller 
and attached storage. 
An immediate reboot 
is strongly 
recommended to 
avoid further 
problems. If the 
reboot does not 
restore 
communication, 
there may be a 
hardware failure.
NOTE: %1 is a 
substitution variable 
that will appear in the 
alert description for 
specific details about 
the alert.
Critical / 
Failure / 
Error
Cause: Storage Management has lost 
communication with a device. There may be 
faulty hardware or loose or defective cables.
Action: Reboot the system. If the problem is 
not resolved, check for hardware failures. Any 
failed component must be replaced. Make 
sure the cables are attached securely. 
See the hardware documentation for more 
diagnostics information.
104 None
2269 The array disk "Clear" 
operation has 
completed.
Ok / 
Normal
Cause: This alert is provided for 
informational purposes.
Action: None
901 None
Table 4-1.  Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap 
Numbers
Array 
Manager 
Event 
Number