2277 The global hot spare 
is too small.
Warning / 
Non-critical
Cause: The global hot spare is not large 
enough to protect all virtual disks that reside 
on the controller.
Action: Assign a larger disk as the global 
hot spare.
903 None
2278 The controller battery 
charge level is below a 
normal threshold.
Critical / 
Failure / 
Error
Cause: The battery is discharging. A battery 
discharge is a normal activity during the 
battery Learn cycle. Before completing, the 
battery Learn cycle recharges the battery. 
You should receive alert 2179 when the 
recharge occurs.
Action: Check if the battery Learn cycle is in 
progress. Alert 2176 indicates that the battery 
Learn cycle has initiated. The battery also 
displays the Learn state while the Learn cycle 
is in progress. If a Learn cycle is not in 
progress, replace the battery pack.
1154 None
2279 The controller battery 
charge level is above a 
normal threshold.
Ok / 
Normal
Cause: This alert is provided for 
informational purposes. This alert indicates 
that the battery is recharging during the 
battery Learn cycle.
Action: None
1151 None
2280 A disk media error has 
been corrected.
Ok / 
Normal
Cause: A disk media error was detected while 
the controller was completing a background 
task. A bad disk block was identified. The 
disk block has been remapped.
Action: Consider replacing the disk. If you 
receive this alert frequently, be sure to replace 
the disk. You should also routinely back up 
your data.
1201 None
2281 Virtual disk has 
inconsistent data.
Ok / 
Normal
Cause: This alert is provided for 
informational purposes.
Action: None
1201 None
Table 4-1.  Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap 
Numbers
Array 
Manager 
Event 
Number