Messages Reference Guide
Table Of Contents
- Dell OpenManage™ Server Administrator
- Messages Reference Guide
- Introduction
 - Event Message Reference
- Miscellaneous Messages
 - Temperature Sensor Messages
 - Cooling Device Messages
 - Voltage Sensor Messages
 - Current Sensor Messages
 - Chassis Intrusion Messages
 - Redundancy Unit Messages
 - Power Supply Messages
 - Memory Device Messages
 - Fan Enclosure Messages
 - AC Power Cord Messages
 - Hardware Log Sensor Messages
 - Processor Sensor Messages
 - Pluggable Device Messages
 
 - System Event Log Messages for IPMI Systems
 - Storage Management Message Reference
 - Index
 
 
 - Messages Reference Guide
 

82 Storage Management Message Reference
2282 Hot spare SMART 
polling failed.
Critical / 
Failure / 
Error
Cause: The controller firmware attempted to 
do SMART polling on the hot spare but was 
unable to complete it. The controller has lost 
communication with the hot spare.
Action: Check the health of the disk assigned 
as a hot spare. You may need to replace the 
disk and reassign the hot spare. Make sure the 
cables are attached securely. 
904 None
2283 A redundant path is 
broken.
Warning / 
Non-critical
Cause: The controller has two connectors 
that are connected to the same enclosure. 
The communication path on one connector 
has lost connection with the enclosure. The 
communication path on the other connector 
is reporting this loss.
Action: Make sure the cables are attached 
securely. 
Make sure both EMMs are healthy.
903 None
2284 A redundant path has 
been restored.
Ok / 
Normal
Cause: This alert is provided for 
informational purposes.
Action: None
901 None
2285 A disk media error 
was corrected during 
recovery.
Ok / 
Normal
Cause: This alert is provided for 
informational purposes.
Action: None
901 None
2286 A Learn cycle start is 
pending while the 
battery charges.
Ok / 
Normal
Cause: This alert is provided for 
informational purposes.
Action: None
1151 None
2287 The "Patrol Read" is 
paused.
Ok / 
Normal
Cause: This alert is provided for 
informational purposes.
Action: None
751 None
2288 The "Patrol Read" has 
resumed.
Ok / 
Normal
Cause: This alert is provided for 
informational purposes.
Action: None
751 None
Table 4-1.  Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap 
Numbers
Array 
Manager 
Event 
Number