Messages Reference Guide
Table Of Contents
- Dell OpenManage™ Server Administrator
- Messages Reference Guide
- Introduction
 - Event Message Reference
- Miscellaneous Messages
 - Temperature Sensor Messages
 - Cooling Device Messages
 - Voltage Sensor Messages
 - Current Sensor Messages
 - Chassis Intrusion Messages
 - Redundancy Unit Messages
 - Power Supply Messages
 - Memory Device Messages
 - Fan Enclosure Messages
 - AC Power Cord Messages
 - Hardware Log Sensor Messages
 - Processor Sensor Messages
 - Pluggable Device Messages
 
 - System Event Log Messages for IPMI Systems
 - Storage Management Message Reference
 - Index
 
 
 - Messages Reference Guide
 

Storage Management Message Reference 85
2299 Bad PHY %1
NOTE: %1 is a 
substitution variable 
that will appear in the 
alert description for 
specific details about 
the alert.
Critical / 
Failure / 
Error
Cause: There is a problem with a physical 
connection or PHY.
Action: Replace the EMM that contains the 
bad PHY. See the hardware documentation 
for information on replacing the EMM. 
Attach the storage to a different connector, if 
available. Make sure the cables are attached 
securely. 
854 None
2300 The enclosure is 
unstable.
Critical / 
Failure / 
Error
Cause: The controller is not receiving a 
consistent response from the enclosure. 
There could be a firmware problem or an 
invalid cabling configuration. If the cables are 
too long, they will degrade the signal.
Action: Power down all enclosures attached 
to the system and reboot the system. If the 
problem persists, upgrade the firmware to the 
latest supported version. You can download 
the most current version of the driver and 
firmware from support.dell.com. Make sure 
the cable configuration is valid. See the 
hardware documentation for valid cabling 
configurations.
854 None
2301 The enclosure has a 
hardware error.
Critical / 
Failure / 
Error
Cause: The enclosure or an enclosure 
component is in a Failed or Degraded state.
Action: Check the health of the enclosure 
and its components. Replace any hardware 
that is in a Failed state. See the hardware 
documentation for more information.
854 None
2302 The enclosure is not 
responding.
Critical / 
Failure / 
Error
Cause: The enclosure or an enclosure 
component is in a Failed or Degraded state.
Action: Check the health of the enclosure 
and its components. Replace any hardware 
that is in a Failed state. See the hardware 
documentation for more information.
854 None
Table 4-1.  Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap 
Numbers
Array 
Manager 
Event 
Number










