Messages Reference Guide
Table Of Contents
- Dell OpenManage™ Server Administrator
- Messages Reference Guide
- Introduction
 - Event Message Reference
- Miscellaneous Messages
 - Temperature Sensor Messages
 - Cooling Device Messages
 - Voltage Sensor Messages
 - Current Sensor Messages
 - Chassis Intrusion Messages
 - Redundancy Unit Messages
 - Power Supply Messages
 - Memory Device Messages
 - Fan Enclosure Messages
 - AC Power Cord Messages
 - Hardware Log Sensor Messages
 - Processor Sensor Messages
 - Pluggable Device Messages
 
 - System Event Log Messages for IPMI Systems
 - Storage Management Message Reference
 - Index
 
 
 - Messages Reference Guide
 

Storage Management Message Reference 87
2309 An array disk is 
incompatible.
Warning / 
Non-critical
Cause: You have attempted to replace a disk 
with another disk that is using an 
incompatible technology. For example, you 
may have replaced one side of a mirror with a 
SAS disk when the other side of the mirror is 
using SATA technology.
Action: See the hardware documentation for 
information on replacing disks.
903 None
2310 A virtual disk is 
permanently 
degraded.
Critical / 
Failure / 
Error
Cause: A redundant virtual disk has lost 
redundancy. This may occur when the virtual 
disk suffers the failure of multiple array disks. 
In this case, both the source array disk and 
the target disk with redundant data have 
failed. A rebuild is not possible because there 
is no longer redundancy.
Action: Replace the failed disks and restore 
from backup.
1204 None
2311 The firmware on the 
EMMs is not the 
same version. EMM0 
%1 EMM1 %2
NOTE: %1 and %2 are 
substitution variables 
that will appear in the 
alert description for 
specific details about 
the alert.
Warning / 
Non-critical
Cause: The firmware on the EMM modules is 
not the same version. It is required that both 
modules have the same version of the 
firmware. This alert may be caused if you 
attempt to insert an EMM module that has a 
different firmware version than an 
existing module.
Action: Upgrade to the same version of the 
firmware on both EMM modules.
853 None
2312 A power supply in the 
enclosure has an 
AC failure.
Warning / 
Non-critical
Cause: The power supply has an AC failure.
Action: Replace the power supply.
1003 None
2313 A power supply in the 
enclosure has a 
DC failure.
Warning / 
Non-critical
Cause: The power supply has a DC failure.
Action: Replace the power supply.
1003 None
Table 4-1.  Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap 
Numbers
Array 
Manager 
Event 
Number