88 Storage Management Message Reference
2314 The initialization 
sequence of SAS 
components failed 
during system 
startup. SAS 
management and 
monitoring is not 
possible.
Critical / 
Failure / 
Error
Cause: Storage Management is unable to 
monitor or manage SAS devices.
Action: Reboot the system. If problem 
persists, make sure you have supported 
versions of the drivers and firmware. Also, you 
may need to reinstall Storage Management or 
Server Administrator because of some 
missing installation components.
104 None
2315 Diagnostic message 
%1
NOTE: %1 is a 
substitution variable 
that will appear in the 
alert description for 
specific details about 
the alert.
Ok / 
Normal
Cause: This alert is provided for 
informational purposes.
Action: None
751 None
2316 Diagnostic message 
%1
NOTE: %1 is a 
substitution variable 
that will appear in the 
alert description for 
specific details about 
the alert.
Critical / 
Failure / 
Error
Cause: A diagnostics test failed. The text for 
this alert is generated by the utility that ran 
the diagnostics.
Action: See the documentation for the utility 
that ran the diagnostics for more 
information.
754 None
2317 BGI terminated due 
to loss of ownership 
in a cluster 
configuration.
Ok / 
Normal
Cause: This alert is provided for 
informational purposes.
Action: None
1201 None
2318 Problems with the 
battery or the battery 
charger have been 
detected. The battery 
health is poor.
Critical / 
Failure / 
Error
Cause: The battery or the battery charger is 
not functioning properly.
Action: Replace the battery pack.
1154 None
Table 4-1.  Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap 
Numbers
Array 