90 Storage Management Message Reference
2324 The AC power supply 
cable has been 
removed.
Critical / 
Failure / 
Error
Cause: The power cable may be pulled out or 
removed. The power cable may also have 
overheated and become warped and 
nonfunctional.
Action: Replace the power cable.
1004 None
2325 The power supply 
cable has been 
inserted.
Ok / 
Normal
Cause: This alert is provided for 
informational purposes.
Action: None
1001 None
2326 A foreign 
configuration has 
been detected.
Ok / 
Normal
Cause: This alert is provided for 
informational purposes. The controller has 
array disks that were moved from another 
controller. These array disks contain virtual 
disks that were created on the other 
controller. See Import Foreign Configuration 
and Clear Foreign Configuration for 
more information.
Action: None
751 None
2327 The NVRAM has 
corrupted data. The 
controller is 
reinitializing the 
NVRAM.
Warning / 
Non-critical
Cause: The NVRAM has corrupted data. This 
may ocurr after a power surge, a battery 
failure, or for other reasons. The controller is 
reinitializing the NVRAM.
Action: None. The controller is taking the 
required corrective action. If this alert is 
generated often (such as during each reboot), 
replace the controller.
753 None
2328 The NVRAM has 
corrupt data.
Warning / 
Non-critical
Cause: The NVRAM has corrupt data. The 
controller is unable to correct the situation.
Action: Replace the controller.
753 None
Table 4-1.  Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap 
Numbers
Array 
Manager 
Event 
Number