Storage Management Message Reference 91
2329 SAS port report: %1
NOTE: %1 is a 
substitution variable 
that will appear in the 
alert description for 
specific details about 
the alert.
Warning / 
Non-critical
Cause: The text for this alert is generated by 
the controller and can vary depending on 
the situation.
Action: Make sure the cables are attached 
securely. 
If the problem persists, replace the cable with 
a valid cable according to SAS specifications. 
If the problem still persists, you may need to 
replace some devices such as the controller or 
EMM. See the hardware documentation for 
more information.
753 None
2330 SAS port report: %1
NOTE: %1 is a 
substitution variable 
that will appear in the 
alert description for 
specific details about 
the alert.
Ok / 
Normal
Cause: This alert is provided for 
informational purposes.
Action: None
751 None
2331 A bad disk block has 
been reassigned.
Warning / 
Non-critical
Cause: The disk has a bad block. Data has 
been readdressed to another disk block and 
no data loss has occurred.
Action: Monitor the disk for other alerts or 
indications of poor health. For example, you 
may receive alert 2306. Replace the disk if 
you suspect there is a problem.
903 None
2332 A controller hot plug 
has been detected.
Ok / 
Normal
Cause: This alert is provided for 
informational purposes.
Action: None
751 None
2333 An enclosure 
temperature sensor 
differential has been 
detected.
Warning / 
Non-critical
Cause: The firmware has detected a 
temperature sensor differential in the 
enclosure.
Action: Monitor the enclosure for other alerts 
related to the temperature. For example, you 
may receive alerts related to the fan or 
temperature probes. Check the health of the 
enclosure and its components. Replace any 
component that is failed.
853 None
Table 4-1.  Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap 
Numbers
Array 