Messages Reference Guide
Table Of Contents
- Dell OpenManage™ Server Administrator
- Messages Reference Guide
- Introduction
 - Event Message Reference
- Miscellaneous Messages
 - Temperature Sensor Messages
 - Cooling Device Messages
 - Voltage Sensor Messages
 - Current Sensor Messages
 - Chassis Intrusion Messages
 - Redundancy Unit Messages
 - Power Supply Messages
 - Memory Device Messages
 - Fan Enclosure Messages
 - AC Power Cord Messages
 - Hardware Log Sensor Messages
 - Processor Sensor Messages
 - Pluggable Device Messages
 
 - System Event Log Messages for IPMI Systems
 - Storage Management Message Reference
 - Index
 
 
 - Messages Reference Guide
 

92 Storage Management Message Reference
2334 Controller event log: 
%1
NOTE: %1 is a 
substitution variable 
that will appear in the 
alert description for 
specific details about 
the alert.
Ok / 
Normal
Cause: This alert is provided for 
informational purposes.
Action: None
751 None
2335 Controller event log: 
%1
NOTE: %1 is a 
substitution variable 
that will appear in the 
alert description for 
specific details about 
the alert.
Warning / 
Non-critical
Cause: The text for this alert is generated by 
the controller and can vary depending on the 
situation. This text is from events in the 
controller event log that were generated while 
Storage Management was not running.
Action: If there is a problem, review the 
controller event log and the Server 
Administrator Alert Log for significant events 
or alerts that may assist in diagnosing the 
problem. Check the health of the storage 
components. See the hardware 
documentation for more information.
753 None
2336 Controller event log: 
%1
NOTE: %1 is a 
substitution variable 
that will appear in the 
alert description for 
specific details about 
the alert.
Critical / 
Failure / 
Error
Cause: The text for this alert is generated by 
the controller and can vary depending on the 
situation. This text is from events in the 
controller event log that were generated while 
Storage Management was not running.
Action: See the hardware documentation for 
more information.
754 None
2337 The controller is 
unable to recover 
cached data from the 
battery backup unit 
(BBU).
Critical / 
Failure / 
Error
Cause: The controller was unable to recover 
data from the cache.
Action: Check if the battery is charged and in 
good health. When the battery charge is 
unacceptably low, it cannot maintain cached 
data. Check if the battery has reached its 
recharge limit. The battery may need to be 
recharged or replaced.
1154 None
Table 4-1.  Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap 
Numbers
Array 
Manager 
Event 
Number