Messages Reference Guide
Table Of Contents
- Dell OpenManage™ Server Administrator
- Messages Reference Guide
- Introduction
 - Event Message Reference
- Miscellaneous Messages
 - Temperature Sensor Messages
 - Cooling Device Messages
 - Voltage Sensor Messages
 - Current Sensor Messages
 - Chassis Intrusion Messages
 - Redundancy Unit Messages
 - Power Supply Messages
 - Memory Device Messages
 - Fan Enclosure Messages
 - AC Power Cord Messages
 - Hardware Log Sensor Messages
 - Processor Sensor Messages
 - Pluggable Device Messages
 
 - System Event Log Messages for IPMI Systems
 - Storage Management Message Reference
 - Index
 
 
 - Messages Reference Guide
 

94 Storage Management Message Reference
2343 The "Check 
Consistency" logging 
of inconsistent parity 
data is disabled.
Warning / 
Non-critical
Cause: The "Check Consistency" operation 
can no longer report errors in the parity data.
Action: See the hardware documentation for 
more information.
1203 None
2344 The virtual disk 
initialization 
terminated.
Warning / 
Non-critical
Cause: A user has cancelled the virtual disk 
initialization.
Action: Restart the initialization.
1203 None
2345 The virtual disk 
initialization failed.
Critical / 
Failure / 
Error
Cause: The controller cannot communicate 
with the attached devices. A disk may be 
removed or contain errors. The cables may 
also be loose or defective.
Action: Check the health of attached devices. 
Review the Alert Log for significant events 
and make sure the cables are attached 
securely. 
1204 None
2346 Error occurred: %1
NOTE: %1 is a 
substitution variable 
that will appear in the 
alert description for 
specific details about 
the alert.
Warning / 
Non-critical
Cause: The text for this alert is generated by 
the firmware and can vary depending on 
the situation.
Action: Check the health of attached devices. 
Review the Alert Log for significant events. 
You may need to replace faulty hardware. 
Make sure the cables are attached securely. 
See the hardware documentation for 
more information.
903 None
2347 The rebuild failed due 
to errors on the 
source physical disk.
Critical / 
Failure / 
Error
Cause: You are attempting to rebuild data 
that resides on a defective disk.
Action: Replace the source disk and restore 
from backup.
904 None
2348 The rebuild failed due 
to errors on the target 
physical disk.
Critical / 
Failure / 
Error
Cause: You are attempting to rebuild data on 
a disk that is defective.
Action: Replace the target disk. If a rebuild 
does not automatically start after replacing 
the disk, initiate the "Rebuild" task. You may 
need to assign the new disk as a hot spare to 
initiate the rebuild.
904 None
Table 4-1.  Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap 
Numbers
Array 
Manager 
Event 
Number










