Messages Reference Guide
Table Of Contents
- Dell OpenManage™ Server Administrator
- Messages Reference Guide
- Introduction
 - Event Message Reference
- Miscellaneous Messages
 - Temperature Sensor Messages
 - Cooling Device Messages
 - Voltage Sensor Messages
 - Current Sensor Messages
 - Chassis Intrusion Messages
 - Redundancy Unit Messages
 - Power Supply Messages
 - Memory Device Messages
 - Fan Enclosure Messages
 - AC Power Cord Messages
 - Hardware Log Sensor Messages
 - Processor Sensor Messages
 - Pluggable Device Messages
 
 - System Event Log Messages for IPMI Systems
 - Storage Management Message Reference
 - Index
 
 
 - Messages Reference Guide
 

Storage Management Message Reference 95
2349 A bad disk block 
could not be 
reassigned during a 
write operation.
Critical / 
Failure / 
Error
Cause: A write operation could not complete 
because the disk contains bad disk blocks 
that could not be reassigned. Data loss may 
have occurred and data redundancy may also 
be lost.
Action: Replace the disk.
904 None
2350 There was an 
unrecoverable disk 
media error during 
the rebuild.
Critical / 
Failure / 
Error
Cause: The rebuild encountered an 
unrecoverable disk media error.
Action: Replace the disk.
904 None
2351 A physical disk is 
marked as missing.
Ok / 
Normal
Cause: This alert is provided for 
informational purposes.
Action: None.
901 None
2352 A physical disk that 
was marked as 
missing has been 
replaced.
Ok / 
Normal
Cause: This alert is provided for 
informational purposes.
Action: None.
901 None
2353 The enclosure 
temperature has 
returned to normal.
Ok / 
Normal
Cause: This alert is provided for 
informational purposes.
Action: None.
851 None
2354 Enclosure firmware 
download in progress.
Ok / 
Normal
Cause: This alert is provided for 
informational purposes.
Action: None.
851 None
Table 4-1.  Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap 
Numbers
Array 
Manager 
Event 
Number










