Messages Reference Guide
Table Of Contents
- Dell OpenManage™ Server Administrator
- Messages Reference Guide
- Introduction
 - Event Message Reference
- Miscellaneous Messages
 - Temperature Sensor Messages
 - Cooling Device Messages
 - Voltage Sensor Messages
 - Current Sensor Messages
 - Chassis Intrusion Messages
 - Redundancy Unit Messages
 - Power Supply Messages
 - Memory Device Messages
 - Fan Enclosure Messages
 - AC Power Cord Messages
 - Hardware Log Sensor Messages
 - Processor Sensor Messages
 - Pluggable Device Messages
 
 - System Event Log Messages for IPMI Systems
 - Storage Management Message Reference
 - Index
 
 
 - Messages Reference Guide
 

96 Storage Management Message Reference
2355 Enclosure firmware 
download failed.The 
system was unable to 
download firmware to 
the enclosure. The 
controller may have 
lost communication 
with the enclosure. 
There may have been 
problems with the 
data transfer or the 
download media may 
be corrupt.
Warning / 
Non-critical
Cause: The system was unable to download 
firmware to the enclosure. The controller may 
have lost communication with the enclosure. 
There may have been problems with the data 
transfer or the download media may be 
corrupt.
Action: Attempt to download the enclosure 
firmware again. If problems continue, check 
if the controller can communicate with the 
enclosure. Make sure that the enclosure is 
powered on. Check the cables and the health 
of the enclosure and its components.
To check the health of the enclosure, select 
the enclosure object in the tree view. The 
Health subtab displays a red X or yellow 
exclamation point for enclosure components 
that are failed or degraded.
853 None
2356 SAS SMP 
communications error 
%1.
NOTE: %1 is a 
substitution variable 
that will appear in the 
alert description for 
specific details about 
the alert.
Critical / 
Failure / 
Error
Cause: The text for this alert is generated by 
the firmware and can vary depending on the 
situation. The reference to SMP in this text 
refers to SAS Management Protocol.
Action: There may be a SAS topology error. 
See the hardware documentation for 
information on correct SAS topology 
configurations. There may be problems with 
the cables such as a loose connection or an 
invalid cabling configuration. See the 
hardware documentation for information on 
correct cabling configurations. Check if the 
firmware is a supported version.
754 None
Table 4-1.  Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap 
Numbers
Array 
Manager 
Event 
Number