2357 SAS expander error: 
%1
NOTE: %1 is a 
substitution variable 
that will appear in the 
alert description for 
specific details about 
the alert.
Critical / 
Failure / 
Error
Cause: The text for this alert is generated by 
the firmware and can vary depending on the 
situation.
Action: There may be a problem with the 
enclosure. Check the health of the enclosure 
and its components. by selecting the 
enclosure object in the tree view. The Health 
subtab displays a red X or yellow exclamation 
point for enclosure components that are 
failed or degraded. See the enclosure 
documentation for more information.
754 None
2358 The battery charge 
cycle is complete.
Ok / 
Normal
Cause: This alert is provided for 
informational purposes.
Action: None.
1151 None
2359 The physical disk is 
not certified.
Warning / 
Non-critical
Cause: The physical disk does not comply 
with the standards set by Dell and is not 
supported.
Action: Replace the physical disk with a 
physical disk that is supported.
903 None
2360 A user has discarded 
data from the 
controller cache.
Ok / 
Normal
Cause: This alert is provided for 
informational purposes.
Action: None.
751 None
2361 Array disk(s) that are 
part of a virtual disk 
have been removed 
while the system was 
shut down. This 
removal was 
discovered during 
system start-up.
Ok / 
Normal
Cause: This alert is provided for 
informational purposes.
Action: None.
751 None
2362 Array disk(s) have 
been removed from a 
virtual disk. The 
virtual disk will be in 
Failed state during 
the next system 
reboot.
Ok / 
Normal
Cause: This alert is provided for 
informational purposes.
Action: None.
751 None
Table 4-1.  Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap 
Numbers
Array 
Manager 
Event 
Number