User's Manual
Using the Storage Management Service 151
Complete Syntax 
omconfig storage vdisk action=assigndedicatedhotspare controller=id 
vdisk=id adisk=<ADISKID> assign=no
where id is the controller ID and virtual disk ID. The <ADISK> variable specifies the array disk. 
To obtain the values for the controller, virtual disk and array disk, you would enter omreport storage 
controller to display the controller IDs and then enter omreport storage vdisk controller=ID and 
omreport storage adisk controller=ID to display the IDs for the virtual disks and array disks attached to 
the controller.
Example Syntax 
In this example, you are unassigning array disk 3 on connector 0 of controller 1 as a dedicated hot spare 
to virtual disk 4. On a SAS controller, the array disk resides in enclosure 2. 
Example for SCSI, SATA, and ATA Controllers: 
To unassign the dedicated hot spare described in this example, enter: 
omconfig storage vdisk action=assigndedicatedhotspare controller=1 
vdisk=4 adisk=0:3 assign=no 
Example for SAS Controllers: 
To unassign the dedicated hot spare described in this example, enter: 
omconfig storage vdisk action=assigndedicatedhotspare controller=1 
vdisk=4 adisk=0:2:3 assign=no 
omconfig Check Consistency 
Use the following omconfig command syntax to initiate a check consistency on a virtual disk. The check 
consistency task verifies the virtual disk’s redundant data. 
Complete Syntax 
omconfig storage vdisk action=checkconsistency controller=id vdisk=
id 
where id is the controller ID and virtual disk ID as reported by the omreport command. To obtain these 
values, enter omreport storage controller to display the controller IDs and then enter omreport storage 
vdisk controller=ID to display the IDs for the virtual disks attached to the controller. 
Example Syntax 
For example, to run a check consistency on virtual disk 4 on controller 1, enter: 
omconfig storage vdisk action=checkconsistency controller=1 vdisk=4 