User's Manual
156 Using the Storage Management Service
omconfig Array Disk Commands 
The following sections provide the omconfig command syntax required to execute array disk tasks. 
omconfig Blink Array Disk 
You can blink the light (light emitting diode or LED display) on one or more array disks attached to a 
controller. Use the following omconfig command syntax to blink one or more array disks. 
Complete Syntax 
action=blink controller=ID action=blink controller=id adisk=
<ADISKID> 
where id is the controller ID. The <ADISK> variable specifies the array disk.
To obtain these values, enter omreport storage controller to display the controller IDs and then enter 
omreport storage adisk controller=ID to display the IDs for the array disks attached to the controller. 
Example Syntax 
In this example, you want to blink array disks 0 through 2 on connector 0 of controller 1. On a SAS 
controller, the array disk resides in enclosure 2. 
Example for SCSI, SATA, and ATA Controllers: 
To blink the array disks described in this example, enter: 
omconfig storage adisk action=blink controller=1 adisk=0:0,0:1,0:2 
Table 8-23. omconfig Array Disk Commands 
Required Command Levels (1, 2, 3) Optional name=value pairs 
omconfig storage adisk
action=blink controller=id adisk=<ADISKID> 
action=unblink controller=id adisk=<ADISKID>
action=remove controller=id adisk=<ADISKID> 
action=initialize controller=id adisk=<ADISKID> 
action=offline controller=id adisk=<ADISKID> 
action=online controller=id adisk=<ADISKID> 
action=assignglobalhotspare controller=id adisk=<ADISKID> 
assign=<yes|no>
action=rebuild controller=id adisk=<ADISKID> 
action=cancelrebuild controller=id adisk=<ADISKID>
action=removedeadsegments controller=id adisk=<ADISKID> 