User's Manual
Using the Storage Management Service 161
Example for SCSI, SATA, and ATA Controllers: 
To assign the array disk described in this example as a global hot spare, enter: 
omconfig storage adisk action=assignglobalhotspare controller=1 
adisk=0:3 assign=yes 
Example for SAS Controllers: 
To assign the array disk described in this example as a global hot spare, enter: 
omconfig storage adisk action=assignglobalhotspare controller=1 
adisk=0:2:3 assign=yes 
omconfig Unassign Global Hot Spare 
Use the following omconfig command syntax to unassign an array disk as a global hot spare. 
Complete Syntax 
omconfig storage adisk action=assignglobalhotspare controller=id 
adisk=<ADISKID> assign=no 
where id is the controller ID. The <ADISK> variable specifies the array disk. 
To obtain these values, enter omreport storage controller to display the controller IDs and then enter 
omreport storage adisk controller=ID to display the IDs for the array disks attached to the controller. 
Example Syntax 
In this example, you want to unassign array disk 3 on connector 0 of controller 1 as a global hot spare. On 
a SAS controller, the array disk resides in enclosure 2. 
Example for SCSI, SATA, and ATA Controllers: 
To unassign the array disk described in this example as a global hot spare, enter: 
omconfig storage adisk action=assignglobalhotspare controller=1 
adisk=0:3 assign=no 
Example for SAS Controllers: 
To unassign the array disk described in this example as a global hot spare, enter: 
omconfig storage adisk action=assignglobalhotspare controller=1 
adisk=0:2:3 assign=no 