Messages Reference Guide

Storage Management Message Reference 101
2319 Single-bit ECC error.
The DIMM is
degrading.
Warni ng /
Non-critical
Cause: The DIMM is beginning to
malfunction.
Action: Replace the DIMM to avoid data loss
or data corruption. The DIMM is a part of
the controller battery pack. See your
hardware documentation for information on
replacing the DIMM.
753 None
2320 Single-bit ECC error.
The DIMM is
critically degraded.
Critical /
Failure /
Error
Cause: The DIMM is malfunctioning.
Data loss or data corruption may be
imminent.
Action: Replace the DIMM immediately to
avoid data loss or data corruption. The
DIMM is a part of the controller battery pack.
See your hardware documentation for
information on replacing the DIMM.
754 None
2321 Single-bit ECC error.
The DIMM is
critically degraded.
There will be no
further reporting.
Critical /
Failure /
Error
Cause: The DIMM is malfunctioning.
Data loss or data corruption is imminent.
The DIMM must be replaced immediately.
No further alerts will be generated.
Action: Replace the DIMM immediately. The
DIMM is a part of the controller battery pack.
See your hardware documentation for
information on replacing the DIMM.
754 None
2322 The DC power supply
is switched off.
Critical /
Failure /
Error
Cause: The power supply unit is switched off.
Either a user switched off the power supply
unit or it is defective.
Action: Check if the power switch is turned
off. If it is turned off, turn it on. If the
problem persists, check if the power cord is
attached and functional. If the problem is
still not corrected or if the power switch is
already turned on, replace the power supply
unit.
1004 None
2323 The power supply is
switched on.
Ok / Normal Cause: This alert is provided for
informational purposes.
Action: None
1001 None
Table 4-1. Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap
Numbers
Array
Manager
Event
Number