Messages Reference Guide

62 Storage Management Message Reference
2070 Virtual disk
initialization
cancelled
Ok / Normal Cause: The virtual disk initialization cancelled
because a physical disk included in the virtual
disk has failed or because a user cancelled the
virtual disk initialization.
Action: If a physical disk failed, then replace
the physical disk. You can identify which disk
has failed by locating the disk that has a
red “X” for its status. Perform a rescan after
replacing the disk. Restart the format array
disk operation. Restart the virtual disk
initialization.
1201 532
2074 Array disk rebuild
cancelled
Ok / Normal Cause: A user has cancelled the rebuild
operation.
Action: Restart the rebuild operation.
901 536
2076 Virtual disk check
consistency failed
Critical /
Failure /
Error
Cause: An array disk included in the virtual
disk failed or there is an error in the parity
information. A failed array disk can cause
errors in parity information.
Action: Replace the failed array disk. You can
identify which disk has failed by locating the
disk that has a red “X” for its status. Rebuild
the array disk. When finished, restart the
check consistency operation.
1204 538
2077 Virtual disk format
failed.
Critical /
Failure /
Error
Cause: An array disk included in the virtual
disk failed.
Action: Replace the failed array disk. You can
identify which array disk has failed by locating
the disk that has a red "X" for its status.
Rebuild the array disk. When finished, restart
the virtual disk format operation.
1204 539
2079 Virtual disk
initialization failed
Critical /
Failure /
Error
Cause: An array disk included in the virtual
disk has failed or a user has cancelled the
initialization.
Action: If an array disk has failed, then
replace the array disk.
1204 541
Table 4-1. Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap
Numbers
Array
Manager
Event
Number