Messages Reference Guide

Storage Management Message Reference 65
2095 SCSI sense data. If
this disk is part of a
redundant virtual
disk, select the
‘Offline’ option and
then replace the disk.
Then configure a hot
spare and it will start
the rebuild
automatically. If this
disk is a hot spare,
select the ‘Prepare to
Remove’ option and
then replace the disk.
If this disk is part of a
non-redundant disk,
you should back up
your data
immediately. If the
disk fails, you will not
be able to recover the
data.
Warni ng /
Non-critical
Cause: An array disk has failed, is corrupt, or
is otherwise experiencing a problem.
Action: Replace the array disk. Even though
the disk may not have failed yet, it is strongly
recommended that you replace the disk.
Review the message text for additional
information.
903 571
2098 Global hot spare
assigned
Ok / Normal Cause: A user has assigned an array disk as a
global hot spare. This alert is provided for
informational purposes.
Action: None
901 574
2099 Global hot spare
unassigned
Ok / Normal Cause: A user has unassigned an array disk as
a global hot spare. This alert is provided for
informational purposes.
Action: None
901 575
Table 4-1. Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap
Numbers
Array
Manager
Event
Number