Messages Reference Guide

68 Storage Management Message Reference
2108 Smart warning Warning /
Non-critical
Cause: A disk has received a SMART alert
(predictive failure). The disk is likely to fail in
the near future.
Action: Replace the disk that has received the
SMART alert. If the array disk is a member of
a non-redundant virtual disk, then back up the
data before replacing the disk. Removing an
array disk that is included in a non-redundant
virtual disk will cause the virtual disk to fail
and may cause data loss.
903 587
2109 SMART warning
temperature
Warni ng /
Non-critical
Cause: A disk has reached an unacceptable
temperature and received a SMART alert
(predictive failure). The disk is likely to fail in
the near future.
First Action: Determine why the array disk
has reached an unacceptable temperature.
A variety of factors can cause the excessive
temperature. For example, a fan may have
failed, the thermostat may be set too high, or
the room temperature may be too hot or cold.
Verify that the fans in the server or enclosure
are working. If the array disk is in an enclosure,
you should check the thermostat settings and
examine whether the enclosure is located
near a heat source. Make sure the enclosure
has enough ventilation and that the room
temperature is not too hot. See the array disk
enclosure documentation for more diagnostic
information.
Second Action: If you cannot identify why the
disk has reached an unacceptable temperature,
then replace the disk. If the array disk is a
member of a non-redundant virtual disk,
then back up the data before replacing the
disk. Removing an array disk that is included
in a non-redundant virtual disk will cause the
virtual disk to fail and may cause data loss.
903 588