Messages Reference Guide

Storage Management Message Reference 81
2171 The controller battery
temperature is above
normal.
Warni ng /
Non-critical
Cause: The battery may be recharging, the
room temperature may be too hot, or the fan
in the system may be degraded or failed.
Action: If this alert was generated due to a
battery recharge, the situation will correct
when the recharge is complete. You should
also check if the room temperature is normal
and that the system components are
functioning properly.
1153 None
2172 The controller battery
temperature is
normal.
Ok / Normal Cause: This alert is provided for
informational purposes.
Action: None
1151 None
2174 The controller battery
has been removed.
Warni ng /
Non-critical
Cause: The controller cannot communicate
with the battery, the battery may be removed,
or the contact point between the controller
and the battery may be burnt or corroded.
Action: Replace the battery if it has been
removed. If the contact point between the
battery and the controller is burnt or corroded,
you will need to replace either the battery or
the controller, or both. See the hardware
documentation for information on how to
safely access, remove, and replace the battery.
1153 None
2175 The controller battery
has been replaced.
Ok / Normal Cause: This alert is provided for
informational purposes.
Action: None
1151 None
2176 The controller battery
Learn cycle has
started.
Ok / Normal Cause: This alert is provided for
informational purposes.
Action: None
1151 None
2177 The controller battery
Learn cycle has
completed.
Ok / Normal Cause: This alert is provided for
informational purposes.
Action: None
1151 None
Table 4-1. Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap
Numbers
Array
Manager
Event
Number