Messages Reference Guide

86 Storage Management Message Reference
2204 A dedicated hot spare
has been removed.
Warni ng /
Non-critical
Cause: The controller is unable to communicate
with a disk that is assigned as a dedicated hot
spare. The disk may have been removed.
There may also be a bad or loose cable.
Action: Check if the disk is healthy and that
it has not been removed. Check the cables. If
necessary, replace the disk and reassign the
hot spare.
903 None
2205 A dedicated hot spare
has been
automatically
unassigned.
Warni ng /
Non-critical
Cause: The hot spare is no longer required
because the virtual disk it was assigned to has
been deleted.
Action: None.
903 None
2206 The only hot spare
available is a
SATA disk. SATA disks
cannot replace
SAS disks.
Warni ng /
Non-critical
Cause: The only array disk available to
be assigned as a hot spare is using
SATA technology. The array disks in the
virtual disk are using SAS technology.
Because of this difference in technology, the
hot spare cannot rebuild data if one of the
array disks in the virtual disk fails.
Action: Add a SAS disk that is large enough
to be used as the hot spare and assign the new
disk as a hot spare.
903 None
2207 The only hot spare
available is a SAS disk.
SAS disks cannot
replace SATA disks.
Warni ng /
Non-critical
Cause: The only array disk available to be
assigned as a hot spare is using SAS technology.
The array disks in the virtual disk are using
SATA technology. Because of this difference
in technology, the hot spare cannot rebuild
data if one of the array disks in the virtual
disk fails.
Action: Add a SATA disk that is large enough
to be used as the hot spare and assign the new
disk as a hot spare.
903 None
Table 4-1. Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap
Numbers
Array
Manager
Event
Number