Messages Reference Guide

Storage Management Message Reference 91
2268 %1, Storage
Management has lost
communication with
this RAID controller
and attached storage.
An immediate
reboot is strongly
recommended to
avoid further problems.
If the reboot does
not restore
communication,
there may be a
hardware failure.
NOTE: %1 is a
substitution variable
that will appear in the
alert description for
specific details about
the alert.
Critical /
Failure /
Error
Cause: Storage Management has lost
communication with a device. There may be
faulty hardware or loose or defective cables.
Action: Reboot the system. If the problem is
not resolved, check for hardware failures. Any
failed component must be replaced. Make
sure the cables are attached securely. See the
hardware documentation for more
diagnostics information.
104 None
2269 The array disk Clear
operation has
completed.
Ok / Normal Cause: This alert is provided for
informational purposes.
Action: None
901 None
2270 The array disk Clear
operation failed.
Critical /
Failure /
Error
Cause: A Clear task was being performed on
an array disk, but it was interrupted and did
not complete successfully. The controller may
have lost communication with the disk. The
disk may have been removed or the cables
may be loose or defective.
Action: Check if the disk is in and not in a
Failed state. Make sure the cables are
attached securely. Restart the Clear task.
904 None
2271 The Patrol Read
corrected a media
error.
Ok / Normal Cause: This alert is provided for
informational purposes.
Action: None
901 None
Table 4-1. Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap
Numbers
Array
Manager