omconfig: Managing Components Using the Instrumentation Service 113
Table 5-23 lists the components and the events for which you can set platform events. Components are
listed in alphabetical order, except that warning events always precede failure events for a component.
Table 5-22. Shutdown Action
Shutdown Action Description
alert=disable Disables the SNMP alert.
alert=enable Enables the SNMP alert to be sent.
action=none Takes no action when the system is hung or has crashed.
action=powercycle Turns the electrical power to the system off, pauses, turns the power
on, and reboots the system.
action=poweroff Turns off the electrical power to the system.
action=reboot Forces the operating system to shut down and initiates system
startup, performs BIOS checks, and reloads the operating system.
Table 5-23. omconfig system platformevents
Event Name Description
alertsenable=true | false true: Enables generation of platform event filter alerts.
false: Disables generation of platform event filter alerts.
NOTE: This setting is independent of the individual platform event filter
alert settings. For a platform event filter to generate an alert, both the
individual alert and the global event alert must be enabled.
event=batterywarn Sets action or enables/disables alert generation when a battery device
detects that the battery is pending a failure condition.
event=batteryfail Sets action or enables/disables alert generation when a battery device
detects that the battery has failed.
event=discretevolt Sets action or enables/disables alert generation when a discrete voltage
probe detects that the voltage is too low for proper operation.
event=fanfail Sets action or enables/disables alert generation when a fan probe detects
that the fan is running too slow or not at all.
event=hardwarelogfail Enables/disables alert generation when a hardware log detects a
failure value.
event=intrusion Sets action or enables/disables alert generation when a chassis has
been opened.
event=powerwarn Sets action or enables/disables alert generation when a power device
probe detects that the power supply, voltage regulator module, or DC to
DC converter is pending a failure condition.