User's Manual

Using the Storage Management Service 161
omreport Temperature Probe Status
omreport Fan Status
Table 9-9. omreport Temperature Probe Commands
Required Command Levels (1, 2, 3)
and name=value pair
Optional name=value pairs Use
omreport storage enclosure Displays property information
for all enclosures attached to
the system.
controller=id enclosure=
<ENCLOSUREID>
info=temps
where id is the controller number
and the enclosure number. For
example: controller=0 enclosure=2
Displays the temperature probes
for the specified enclosure.
controller=id enclosure=
<ENCLOSUREID>
info=temps index=n
where id is the controller number
and the enclosure number and “n” is
the number of a temperature probe.
For example: controller=0
enclosure=2 info=temps index=1
Displays the specified
temperature probe.
Table 9-10. omreport Fan Status
Required Command Levels (1, 2, 3)
and name=value pair
Optional name=value pairs Use
omreport storage enclosure Displays property information for
all enclosures attached to the system.
controller=id enclosure=
<ENCLOSUREID> info=fans
where id is the controller number
and the enclosure number.
For example: controller=0
enclosure=2
NOTE: For SCSI controllers, the ID
specified in enclosure=
<ENCLOSUREID> is the connector
number and for Serial Attached
SCSI (SAS) controllers, ID is the
connectorNumber:EnclosureIndex.
Displays the fans for the specified
enclosure.