User's Manual

184 Using the Storage Management Service
Complete Syntax
omconfig storage vdisk action=assigndedicatedhotspare controller=id
vdisk=id adisk=<ADISKID> assign=no
where id is the controller ID and virtual disk ID. The <ADISK> variable specifies the array disk.
To obtain the values for the controller, virtual disk, and array disk, enter omreport storage controller to
display the controller IDs and then enter omreport storage vdisk controller=ID and omreport storage
adisk controller=ID to display the IDs for the virtual disks and array disks attached to the controller.
Example Syntax
In this example, you are unassigning array disk 3 on connector 0 of controller 1 as a dedicated hot spare
to virtual disk 4. On a SAS controller, the array disk resides in enclosure 2.
Example for SCSI, SATA, and ATA Controllers:
To unassign the dedicated hot spare described in this example, enter:
omconfig storage vdisk action=assigndedicatedhotspare controller=1
vdisk=4 adisk=0:3 assign=no
Example for SAS Controllers:
To unassign the dedicated hot spare described in this example, enter:
omconfig storage vdisk action=assigndedicatedhotspare controller=1
vdisk=4 adisk=0:2:3 assign=no
omconfig Check Consistency
Use the following omconfig command syntax to initiate a check consistency on a virtual disk. The check
consistency task verifies the virtual disk’s redundant data.
Complete Syntax
omconfig storage vdisk action=checkconsistency controller=id vdisk=
id
where id is the controller ID and virtual disk ID as reported by the omreport command. To obtain these
values, enter omreport storage controller to display the controller IDs and then enter omreport storage
vdisk controller=ID to display the IDs for the virtual disks attached to the controller.
Example Syntax
For example, to run a check consistency on virtual disk 4 on controller 1, enter:
omconfig storage vdisk action=checkconsistency controller=1 vdisk=4