Using the Storage Management Service 199
omconfig Connector Commands
The following sections provide the omconfig command syntax required to execute connector tasks.
omconfig Rescan Connector
Use the following omconfig command to rescan a controller connector. This command rescans all
connectors on the controller and is therefore similar to performing a controller rescan.
NOTE: This command is not supported on SAS controllers.
Complete Syntax
omconfig storage connector action=rescan controller=id connector=id
where id is the controller ID and the connector ID as reported by the omreport command. To obtain
these values, enter omreport storage controller to display the controller IDs and then enter omreport
storage connector controller=ID to display the IDs for the connectors attached to the controller.
Example Syntax
For example, to rescan connector 2 on controller 1, enter:
omconfig storage connector action=rescan controller=1 connector=2
omconfig Enclosure Commands
The following sections provide the omconfig command syntax required to execute enclosure tasks.
Table 9-25. omconfig Connector Commands
Required Command Levels (1, 2, 3) Optional name=value pairs
omconfig storage connector
action=rescan controller=id connector=id
Table 9-26. omconfig Enclosure Commands
Required Command Levels (1, 2, 3) Optional name=value pairs
omconfig storage enclosure
action=enablealarm controller=id enclosure=<ENCLOSUREID>
action=disablealarm controller=id enclosure=<ENCLOSUREID>
action=enablests
action=disablests
action=setassettag controller=id enclosure=<ENCLOSUREID>
assettag=<string>