User's Manual

omconfig: Managing Components Using the Instrumentation Service 81
Ty p e :
omconfig chassis bmc
The output from the omconfig chassis bmc command lists each of the available configurations.
Table 5-3 shows the valid parameters:
Table 5-3. omconfig chassis bmc
name=value pair 1
config=
name=value pair 2 Description
config=advsol characcuminterval=number number: Sets the character
accumulate interval in 5 millisecond
intervals.
charsendthreshold=number number: Sets the number of
characters. BMC automatically sends
a serial over LAN data packet that
contains this number of characters as
soon as this number of characters
(or greater) has been accepted from
the baseboard serial controller into
the BMC.
config=nic enable=true | false true: Enables IPMI over LAN.
false: Disables IPMI over LAN.
encryptkey=text text: Text to encrypt IPMI sessions.
NOTE: The option text is supported
only on PowerEdge 1900, 1950, 1955,
2900, and 2950 systems.
gateway=gateway Gateway: Sets a gateway address if you
have selected static as the IP address
source for the BMC LAN interface.
enablenic=true | false true: Enables the DRAC NIC.
false: Disables the DRAC NIC
NOTE: The option enablenic is
supported only on PowerEdge
1900,1950, 1955, 2900, and 2950 systems
that have DRAC installed.
IP address=IP IP: Sets the IP address if you have
selected static as the IP address source
for the BMC LAN interface.