Users Guide

108 Storage Management Service
To locate this task in Storage Management
1
Expand the
Storage
tree object to display the controller objects.
2
Expand a controller object.
3
Select the
Virtual Disks
object.
4
Select
Assign/Unassign Dedicated Hot Spare
from the
Available Tasks
drop-down menu.
5
Click
Execute
.
See the Storage Management online help for more information.
Rebuild a Failed Array Disk
If the failed array disk is part of a redundant virtual disk, then the array disk failure should not result in
data loss if replaced immediately. The rebuild task is available when the Array Disks object is selected.
See the Storage Management online help for more information.
Global Tasks
The following global tasks are available when the Storage object is selected. See the Storage
Management online help for more information.
Global Rescan.
A global rescan updates configuration changes (such as new or removed devices) for all
controllers and their attached components.
Enable and Disable Smart Thermal Shutdown.
By default, the operating system and server shut down
when the PV220S and PV221S enclosures reach a critical temperature of 0 or 50 degrees celsius. Using
the Enable Smart Thermal Shutdown task, however, you can specify that only the enclosure and not
the operating system and server be shut down when the enclosure reaches a critical temperature. To
restore the system to its default setting use the Disable Smart Thermal Shutdown task.
Controller Tasks
The following controller tasks are available when the Controller object is selected. See the Storage
Management online help for more information.
Rescan Controller.
A controller rescan updates configuration changes (such as new or removed
devices) for all components attached to the controller.
Create Virtual Disk.
See "Create Virtual Disk Wizard."
Enable, Disable, Quiet, and Test Alarm.
These tasks enable you to manage the controller alarm. For
example, you can set the alarm to sound in the event of a device failure or quiet the alarm once it is
sounding.
Set Rebuild Rate.
The rebuild rate refers to how much of the system's resources are dedicated to
rebuilding a failed array disk. This task enables you to adjust this setting.
Reset Configuration.
This task erases all information on the controller, so that you can perform a fresh
configuration. This operation destroys all virtual disks on the controller.
Export Log File.
This task exports the controller log to a text file.