Reference Guide

Power Group 155
Table 8-13. AC Power Cord State Capabilities
Variable Name: DellACPowerCordStateCapabilities
Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1) The AC power cord’s capabilities are unknown.
onlineCapable(2) The AC power cord can be disabled (offline) or enabled (online).
notReadyCapable(4) The AC power cord’s capabilities are not ready.
Table 8-14. AC Power Cord State Settings
Variable Name: DellACPowerCordStateSettings
Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1) The AC power cord’s state is unknown.
online(2) The AC power cord’s state is disabled (offline) 0 or enabled (online) 1.
notReady(4) The AC power cord’s state is not ready.
acPowerCordHasPower(8) The AC power cord has power.
acPowerCordIsActiveSource(16) The AC power cord is the active source of AC power.
Table 8-15. Battery Reading
Variable Name:
DellBatteryReading
Data Type: Integer
NOTE: These values are bit masks, so combination values are possible.
Possible Data Values Meaning of Data Value
predictiveFailure(1) Battery sensor detects predictive failure.
failed(2) Battery has failed.
presenceDetected(4) Battery presence is detected.