576 Traps
Temperature Probe Traps
Temperature probes help protect critical components by alerting the systems management console when
temperatures become too high inside a chassis. The temperature probe traps use additional variables:
sensor location, chassis location, previous state, and temperature sensor value reported in degrees Celsius.
Table 25-3. Temperature Probe Traps
Trap ID Description Severity Cause
Temperature Probe Normal
1052 Temperature sensor returned to a
normal value
Sensor location: <
Location in chassis
>
Chassis location: <
Name of chassis
>
Previous state was: <
State
>
If sensor type is not discrete:
Temperature sensor value (in degrees
Celsius):
<Reading>
If sensor type is discrete: Discrete
temperature state:
<State>
Information A temperature sensor on the
backplane board, system
board, or drive carrier in the
specified system returned to a
valid range after crossing a
failure threshold. The sensor
location, chassis location,
previous state, and
temperature sensor value are
provided.
Temperature Probe Warning
1053 Temperature sensor detected a
warning value
Sensor location: <
Location in chassis
>
Chassis location: <
Name of chassis
>
Previous state was: <
State
>
If sensor type is not discrete:
Temperature sensor value (in degrees
Celsius):
<Reading>
If sensor type is discrete: Discrete
temperature state:
<State>
Warning A temperature sensor on the
backplane board, system
board, or drive carrier in the
specified system exceeded its
warning threshold. The sensor
location, chassis location,
previous state, and
temperature sensor value are
provided.