Reference Guide

Traps 597
BMC Traps
The BMC monitors the system for critical events by communicating with various sensors on the system
board and by sending alerts and log events when certain parameters exceed their preset thresholds. All of
the traps documented in this section belong to the MIB enterprise identified by OID
1.3.6.1.4.1.3183.1.1.1.
Table 25-19. BMC Traps
Trap ID Description Severity
262402 Generic Critical Fan Failure Critical
262530 Generic Critical Fan Failure Cleared Informational
131330 Under-Voltage Problem (Lower Critical - going low) Critical
131458 Under-Voltage Problem Cleared Informational
131841 Generic Critical Voltage Problem Critical
131840 Generic Critical Voltage Problem Cleared Informational
65792 Under-Temperature Warning (Lower non-critical, going low) Wa rning
65920 Under-Temperature Warning Cleared Informational
65794 Under-Temperature Problem (Lower Critical - going low) Critical
65922 Under-Temperature Problem Cleared Informational
65799 Over-Temperature warning (Upper non-critical, going high) Minor
65927 Over-Temperature warning Cleared Informational
65801 Over-Temperature Problem (Upper Critical - going high) Critical
65929 Over-Temperature Problem Cleared Informational
131328 Under-Voltage Warning (Lower Non Critical - going low) Wa rn in g
131456 Under-Voltage Warning Cleared Informational
131330 Under-Voltage Problem (Lower Critical - going low) Critical
131458 Under-Voltage Problem Cleared Informational
131335 Over-Voltage Warning (Upper Non Critical - going high) Wa rning
131463 Over-Voltage Warning Cleared Informational
131337 Over-Voltage Problem (Upper Critical - going high) Critical
131465 Over-Voltage Problem Cleared Informational
131841 Generic Critical Voltage Problem Critical
131840 Generic Critical Voltage Problem Cleared Informational
356096 Chassis Intrusion - Physical Security Violation Critical