Reference Guide

Storage Management Alert Reference 619
2140 Dead disk
segments
restored
OK/Normal/
Informational
Cause: Disk space that was formerly “dead” or
inaccessible to a redundant virtual disk has been
restored. This alert is provided for informational purposes.
Action: None.
1201 None
2141 Array disk
dead segments
recovered
OK/Normal/
Informational
Cause: Portions of the array disk that were formerly
inaccessible have been recovered. Any data residing on
these dead segments has been lost.This alert is
provided for informational purposes.
Action: None.
901 None
2142 Controller
rebuild rate
has changed
OK/Normal/
Informational
Cause: A user has changed the controller rebuild rate.
This alert is provided for informational purposes.
Action: None.
751 680
2143 Controller
alarm enabled
OK/Normal/
Informational
Cause: A user has enabled the controller alarm.
This alert is provided for informational purposes.
Action: None.
751 678
2144 Controller
alarm disabled
OK/Normal/
Informational
Cause: A user has disabled the controller alarm.
This alert is provided for informational purposes.
Action: None.
751 679
2145 Controller
battery low
Warning /
Non-critical
Cause: The controller battery charge is low. On
batteries that automatically recharge or recondition,
this alert may indicate that the recharge limit has
been reached.
Action: Recondition the battery. See the online help for
more information
1153 580
2146 Bad block
replacement
error
Warning /
Non-critical
Cause: A portion of an array disk is damaged.
Action: See the Storage Management online help or
the Dell OpenManage™ Server Administrator Storage
Management User's Guide for more information.
753 691
2147 Bad block
sense error
Warning /
Non-critical
Cause: A portion of an array disk is damaged. See the
online help for more information.
Action: See the online help for more information.
753 691
2148 Bad block
medium error
Warning /
Non-critical
Cause: A portion of an array disk is damaged. See the
online help for more information.
Action: See the online help for more information.
753 691
Table 26-2. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action SNMP
Trap
Numbers
Array
Manager
Event
Number