Reference Guide

632 Storage Management Alert Reference
2255 The array disk
has started.
OK/Normal/
Informational
Cause: This alert is provided for informational purposes.
Action: None.
901 None
2259 An enclosure
blink
operation has
initiated.
OK/Normal/
Informational
Cause: This alert is provided for informational purposes.
Action: None.
851 None
2260 An enclosure
blink has
ceased.
OK/Normal/
Informational
Cause: This alert is provided for informational purposes.
Action: None.
851 None
2261 A global
rescan has
initiated.
OK/Normal/
Informational
Cause: This alert is provided for informational purposes.
Action: None.
101 None
2262 Smart thermal
shutdown is
enabled.
OK/Normal/
Informational
Cause: This alert is provided for informational purposes.
Action: None.
101 None
2263 Smart thermal
shutdown is
disabled.
OK/Normal/
Informational
Cause: This alert is provided for informational purposes.
Action: None.
101 None
2264 A device is
missing.
Wa rn ing/
Non-critical
Cause: The controller cannot communicate with a
device. The device may be removed. There may also be
a bad or loose cable.
Action: Verify that the device is present and not
removed. If it is present, then check the cables. You
should also check the connection to the controller
battery and the battery health. A battery with a weak or
depleted charge may cause this alert.
753, 803,
853, 903,
953, 1003,
1053,
1103,
1153,
1203
None