640 Storage Management Alert Reference
2299 Bad PHY %1.
The %1
indicates a
substitution
variable. The
text for this
substitution
variable is
displayed with
the alert in the
Alert Log and
can vary
depending on
the situation.
Critical/
Failure/
Error
Cause: There is a problem with a physical connection
or PHY.
Action: Replace the EMM that contains the bad PHY.
See the hardware documentation for information on
replacing the EMM. Attach the storage to a different
connector if one is available. Make sure the cables are
attached securely.
854 None
2300 The enclosure
is unstable.
Critical/
Failure/
Error
Cause: The controller is not receiving a consistent
response from the enclosure. There could be a firmware
problem or an invalid cabling configuration. If the
cables are too long, they will degrade the signal.
Action: Completely power down all enclosures attached
to the system and reboot the system. If the problem
persists, upgrade the firmware to the latest supported
version. You can download the most current version of
the driver and firmware from support.dell.com. Make
sure the cable configuration is valid. See the hardware
documentation for valid cabling configurations.
854 None
2301 The enclosure
has a hardware
error.
Critical/
Failure/
Error
Cause: The enclosure or an enclosure component is in a
Failed or Degraded state.
Action: Verify the health of the enclosure and its
components. Replace any hardware that is in a Failed
state. See the hardware documentation for more
information.
854 None
2302 The enclosure
is not
responding.
Critical/
Failure/
Error
Cause: The enclosure or an enclosure component is in a
Failed or Degraded state.
Action: Verify the health of the enclosure and its
components. Replace any hardware that is in a Failed
state. See the hardware documentation for more
information.
854 None
Table 26-2. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action SNMP
Trap
Numbers
Array
Manager
Event