Reference Guide

Storage Management Message Reference 105
2311 The firmware on the
EMMs is not the
same version. EMM0
%1 EMM1 %2
Warning /
Non-critical
Cause: The firmware on the EMM modules
is not the same version. It is required that
both modules have the same version of the
firmware. This alert may be caused if you
attempt to insert an EMM module that has a
different firmware version than an existing
module. The %1 and %2 indicate a
substitution variable. The text for these
substitution variables is displayed with the
alert in the Alert Log and can vary depending
on the situation.
Action: Upgrade to the same version of the
firmware on both EMM modules.
None 853
2312 A power supply in
the enclosure has an
AC failure.
Warning /
Non-critical
Cause: The power supply has an AC failure.
Action: Replace the power supply.
2325 1003
2313 A power supply in
the enclosure has a
DC failure.
Warning /
Non-critical
Cause: The power supply has a DC failure.
Action: Replace the power supply.
2323 1003
2314 The initialization
sequence of SAS
components failed
during system
startup. SAS
management and
monitoring is not
possible.
Critical /
Failure /
Error
Cause: Storage Management is unable to
monitor or manage SAS devices.
Action: Reboot the system. If problem
persists, make sure you have supported
versions of the drivers and firmware. Also, you
may need to reinstall Storage Management or
Server Administrator because of some
missing installation components.
None 104
2315 Diagnostic message
%1
Ok / Normal Cause: This alert is for informational
purposes. The %1 indicates a substitution
variable. The text for this substitution
variable is generated by the utility that ran
the diagnostics and is displayed with the alert
in the Alert Log. This text can vary
depending on the situation.
Action: None
None 751
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Clear
Event
Number
SNMP
Trap
Numbers