Reference Guide

106 Storage Management Message Reference
2316 Diagnostic message
%1
Critical /
Failure /
Error
Cause: A diagnostics test failed. The %1
indicates a substitution variable. The text for
this substitution variable is generated by the
utility that ran the diagnostics and is
displayed with the alert in the Alert Log. This
text can vary depending on the situation.
Action: See the documentation for the utility
that ran the diagnostics for more
information.
None 754
2317 BGI terminated due
to loss of ownership
in a cluster
configuration.
Ok / Normal Cause: This alert is for informational purposes.
Action: None
None 1201
2318 Problems with the
battery or the battery
charger have been
detected. The
battery health is
poor.
Critical /
Failure /
Error
Cause: The battery or the battery charger is
not functioning properly.
Action: Replace the battery pack.
None 1154
2319 Single-bit ECC error.
The DIMM is
degrading.
Warning /
Non-critical
Cause: The DIMM is beginning to
malfunction.
Action: Replace the DIMM to avoid data loss
or data corruption. The DIMM is a part of
the controller battery pack. See your
hardware documentation for information on
replacing the DIMM.
None 753
2320 Single-bit ECC error.
The DIMM is
critically degraded.
Critical /
Failure /
Error
Cause: The DIMM is malfunctioning.
Data loss or data corruption may be
imminent.
Action: Replace the DIMM immediately to
avoid data loss or data corruption. The
DIMM is a part of the controller battery pack.
See your hardware documentation for
information on replacing the DIMM.
None 754
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Clear
Event
Number
SNMP
Trap
Numbers