Reference Guide

Storage Management Message Reference 109
2331 A bad disk block has
been reassigned.
Warning /
Non-critical
Cause: The disk has a bad block. Data has
been readdressed to another disk block and
no data loss has occurred.
Action: Monitor the disk for other alerts or
indications of poor health. For example, you
may receive alert 2306. Replace the disk if
you suspect there is a problem.
None 903
2332 A controller hot plug
has been detected.
Ok / Normal Cause: This alert is for informational purposes.
Action: None
None 751
2333 An enclosure
temperature sensor
differential has been
detected.
Warning /
Non-critical
Cause: The firmware has detected a
temperature sensor differential in the
enclosure.
Action: Monitor the enclosure for other alerts
related to the temperature. For example, you
may receive alerts related to the fan or
temperature probes. Check the health of the
enclosure and its components. Replace any
component that is failed.
None 853
2334 Controller event
log: %1
Ok / Normal Cause: This alert is for informational
purposes. The %1 indicates a substitution
variable. The text for this substitution
variable is generated by the controller and is
displayed with the alert in the Alert Log. This
text is from events in the controller event log
that were generated while Storage
Management was not running. This text can
vary depending on the situation.
Action: None
None 751
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Clear
Event
Number
SNMP
Trap
Numbers