Reference Guide

Storage Management Message Reference 67
2064 Virtual disk rebuild
started
Ok / Normal Cause: This alert is for informational purposes.
Action: None
2091 1201
2065 Physical disk rebuild
started
Ok / Normal Cause: This alert is for informational purposes.
Action: None
2092 901
2067 Virtual disk check
consistency
cancelled
Ok / Normal Cause: The check consistency operation
cancelled because a physical disk in the array
has failed or because a user cancelled the
check consistency operation.
Action: If the physical disk failed, then replace
the physical disk. You can identify which disk
failed by locating the disk that has a red “X”
for its status. Perform a rescan after replacing
the disk. When performing a consistency
check, be aware that the consistency check
can take a long time. The time it takes
depends on the size of the physical disk or
the virtual disk.
None 1201
2070 Virtual disk
initialization
cancelled
Ok / Normal Cause: The virtual disk initialization cancelled
because a physical disk included in the virtual
disk has failed or because a user cancelled the
virtual disk initialization.
Action: If a physical disk failed, then replace
the physical disk. You can identify which disk
has failed by locating the disk that has a
red “X” for its status. Perform a rescan after
replacing the disk. Restart the format
physical disk operation. Restart the virtual
disk initialization.
None 1201
2074 Physical disk rebuild
cancelled
Ok / Normal Cause: A user has cancelled the rebuild
operation.
Action: Restart the rebuild operation.
None 901
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Clear
Event
Number
SNMP
Trap
Numbers