Reference Guide

Storage Management Message Reference 69
2082 Virtual disk rebuild
failed
Critical /
Failure /
Error
Cause: A physical disk included in the virtual
disk has failed or is corrupt. A user may also
have cancelled the rebuild.
Action: Replace the failed or corrupt disk.
You can identify a disk that has failed by
locating the disk that has a red “X” for its
status. Restart the virtual disk rebuild.
None 1204
2083 Physical disk rebuild
failed
Critical /
Failure /
Error
Cause: A physical disk included in the virtual
disk has failed or is corrupt. A user may also
have cancelled the rebuild.
Action: Replace the failed or corrupt disk.
You can identify a disk that has failed by
locating the disk that has a red “X” for its
status. Rebuild the virtual disk rebuild.
None 904
2085 Virtual disk check
consistency
completed
Ok / Normal Cause: This alert is for informational purposes.
Action: None
Clear
event
1201
2086 Virtual disk format
completed
Ok / Normal Cause: This alert is for informational purposes.
Action: None
Clear
event
1201
2088 Virtual disk
initialization
completed
Ok / Normal Cause: This alert is for informational purposes.
Action: None
Clear
event
1201
2089 Physical disk
initialize completed
Ok / Normal Cause: This alert is for informational purposes.
Action: None
Clear
event
901
2090 Virtual disk
reconfiguration
completed
Ok / Normal Cause: This alert is for informational purposes.
Action: None
Clear
event
1201
2091 Virtual disk rebuild
completed
Ok / Normal Cause: This alert is for informational purposes.
Action: None
Clear
event
1201
2092 Physical disk rebuild
completed
Ok / Normal Cause: This alert is for informational purposes.
Action: None
Clear
event
901
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Clear
Event
Number
SNMP
Trap
Numbers